Fraud Blocker

Top High Voltage Isolation Transformer Manufacturers and Suppliers in China

High Voltage Isolation Transformer

DEMIKS give dependable, quick, and secure isolation transformers tailored to your high voltage requirements. Moreso, our transformers achieve the strict industry benchmarks for safety and performance. Contact us to find out how our products can transform your operations.

DLB-10-400kV-D

DLB-10-400kV-D

  • Safety Performance: Entrapment of hazardous voltage wherein no electric shock can be sustained; secondary side is floating.

  • Electrical Insulation: Prevents risks of unintended earthing; primary and secondary sides fully isolated.

  • Filtering Effect: Input and output are kept separate to ensure the provision of clean voltage.

  • Anti-Interference Function: Uses iron core construction to attenuate high frequency interference signals.

Parameter NameParameter Value
Input Voltage220V
Input Current45.5A
Number of PhasesSingle Phase
Output Voltage220V
Output Current45.5A
Rated Capacity10kVA
Frequency50±5Hz
ModelHZLB-10kVA/400kV-0.22/0.22kV
Withstand Voltage between Primary and SecondaryDC400kV
Voltage Ratio220/220(V)
External StructureVertical Type
Cooling MethodONAN

DLB-25kVA 300kV

  • Safety: Protects against electric shock on the primary side by dangerous voltage; secondary side ungrounded.

  • Insulation: Fully separates primary and secondary circuits which mitigates grounding risks.

  • Filtering: Provides clean power by separating input from output circuits.

  • Applications: Useful in subway and airport industries as well as tunnel construction.

DLB-25kVA300kV
Parameter NameParameter Value
Input Voltage380V
Input Current37.9A
Number of PhasesThree - Phase
Output Voltage380V
Output Current37.9A
Rated Capacity25kVA
Frequency50±5Hz
ModelDLB-25kVA/300kV-0.38/0.38kV
Withstand Voltage between Primary and SecondaryDC300kV
Voltage Ratio380/380(V)
External StructureVertical Type
Cooling MethodONAN
DLB-30-300kV-D

DLB-30-300kV-D

  • Definition: Electromagnetically isolating the input and output windings.

  • Safety: Shields from risk from inadvertent interaction.

  • Applications: Assists in the maintenance and servicing of machines.

  • Functions: Provides protective functions, lightning protection, and filtering.

  • Areas of Application: Subways, buildings, airports, stations, docks, industries, and tunnels.

Parameter NameParameter Value
Input Voltage220V
Input Current136.4A
Number of PhasesSingle Phase
Output Voltage220V
Output Current136.4A
Rated Capacity30kVA
Frequency50±5Hz
ModelHZLB-30KVA/300kV-0.22/0.22kV
Withstand Voltage between Primary and SecondaryDC300kV
Voltage Ratio220/220(V)
External StructureVertical Type
Cooling MethodONAN

DLB-30-300kV-S

  • Electrical Insulation: No relation or link exists between primary and secondary sides.

  • Filtering: Input and output wil be separated, ensuring no power supply contamination.

  • Anti-Interference: High frequency noises are suppressed due to iron core characteristics.

DLB-30-300kV-S
Parameter NameParameter Value
Input Voltage380V
Input Current45A
Number of PhasesThree - Phase
Output Voltage380V
Output Current45.6A
Rated Capacity30kVA
Frequency50±5Hz
ModelHZLB - 30kVA/300kV - 0.38/0.38kV
Withstand Voltage between Primary and SecondaryDC300kV
Voltage Ratio380/380(V)
External StructureVertical Type
Cooling MethodONAN