Fraud Blocker

Top Transformer Winding DC Resistance Tester Manufacturers and Suppliers in China

Transformer Winding DC Resistance Tester

For a reliable and accurate method for testing transformer winding DC resistance, look no further than DEMIKS. As one of the leading manufacturers and suppliers in China, we provide the market with advanced transformer winding DC resistance testers that will satisfy your testing requirements. The performance of the testers is guaranteed in terms of accuracy and precision of measurement. Let DEMIKS serve you with all the transformer winding tests you require. Contact us today and find out how our testers can improve your operations.

D210-2A

D210-2A Winding Resistance Tester

  • Efficiency Improvement: Saves time with a rapid measurement process during transformer testing.

  • System Security: Permit comprehensive protection function for perfect protective covering.

  • Integrated Printing: Result printing is made easy with a panel type micro printer.

  • Safety Design: Protects against misoperation with automatic discharge and indicator functions ensuring safe operation.

  • Effective noise immunity: Have strong anti-interference capabilities for reliable results.

  • Effective and Precise: Provides fast and precise measurements with superior data repeatability.

ModeMeasurement RangeMeasurement CurrentPower SourceMeasurement AccuracyDisplay and Printing
D210-1A0mΩ~2000Ω0.001~1AAC and DC dual purpose with lithium-ion rechargeable battery0.2%±2 bit (25±2℃)Digital
D210-2A0mΩ~2000Ω0.002~2AAC and DC dual purpose with lithium-ion rechargeable battery0.2%±2 bit (25±2℃)Crystal
D210-3A0mΩ~2000Ω0.003~3AAC and DC dual purpose with lithium-ion rechargeable battery0.2%±2 bit (25±2℃)Crystal
D210-5A1mΩ~500Ω0.04~5AAC and DC dual purpose with lithium-ion rechargeable battery0.2%±2 bit (25±2℃)Crystal with printer
D210-10A0.2mΩ~10Ω0.2~10AAC220±10% 45Hz—60Hz0.2%±2 bit (25±2℃)Crystal with printer
D210-20A0.1mΩ~8Ω1~20AAC220±10% 45Hz—60Hz0.2%±2 bit (25±2℃)Crystal with printer
D210-40A0.05mΩ~4Ω5~40AAC220±10% 45Hz—60Hz0.2%±2 bit (25±2℃)Crystal with printer
D220-10A0.2mΩ~10Ω0.2~10AAC220±10% 45Hz—60Hz0.2%±2 bit (25±2℃)Crystal with printer

D210-10A Resistance tester

  • Critical for Transformer Testing: Optimal for transformers and high power inductive apparatus winding DC resistance measurement prior to shipping.

  • Simultaneous Measurement of Three-Phase: Measures YN three-phase DC resistance simultaneously, greatly minimizing the time spent on testing.

  • Rapid and Precise: Guarantees the measurements are rapid and precise, with the premier data reproducibility.

  • Strong Anti-Interference: Provides a robust degree of anti-interference without compromising dependability.

  • Safety Features: Offers automatic discharge and discharge indication functions which eliminate the possibility of misoperation while providing safety.

D210-10A
D210-20A

D210-20A DC Resistance Tester

  • Applications: Best suited for maintenance of transformers, testing electric equipment, and working in power plants, transformer manufacturing, and repair shops.

  • Key Features: Compact size, integrated display and printing system, automation friendly, precision measurements (0.2 ± 0.02), and multi-range resistance measurement from (0.1mΩ to 80Ω) and high current output from (1A to 20A) with outstanding flexibility.

  • Specifications: Works at AC220V ±10% 45Hz–60Hz with a crystal display. Equipped with a built-in printer and measures resistance with high precision.

D210-40A Winding resistance tester

  • Efficient and accurate testing: With the capability to measure DC resistance of transformer windings with high precision (±0.2%) and with a rate of speed of 0.05mΩ to 4Ω, the D210-40A supports currents of 5A to 40A.

  • Safety and portability: Designed with automatic discharge features for user safety, the unit is also equipped with a rechargeable battery, enabling use under AC or DC power conditions, enhancing convenience and usability on the go.

  • Convenient features: Features strong anti-interference, three phase measurement, and a built-in printer for immediate output documentation.

D210-40A
D210-ST10A

D210-ST10A winding DC resistance tester

  • Purpose and Application: The D210-ST10A is essential for transformer handover tests, measuring DC resistance in transformer windings, and performing the handover test for high-powered inductive apparatuses systems.

  • Key Features: It offers three-phase measurement simultaneity, fast and accurate testing, ample anti-interference, automatic discharge safety mechanisms, and a micro printer for documentation.

  • Specifications and Usability: It retains versatility and user-friendliness with a wide range of measurement, multiple current levels, compact design (9kg), operable temperatures from -10℃ to 50℃, and flexible for various sizes of transformers.

Technical SpecificationsDetails
Output CurrentSingle-phase: 20A, 10A, 5A, 1A, 0.1A, 10mA, <1mA,Three-phase: 10A+10A, 5A+5A, 1A+1A, 0.1A+0.1A
Measurement Range20A range: 0.5mΩ~1Ω, 10A range: 1.0mΩ~2Ω, 5A range: 10mΩ~4Ω, 1A range: 0.1Ω~20Ω, 0.1A range: 2.0Ω~200Ω, 10mA range: 50Ω~2kΩ, <1mA range: 500Ω~25kΩ; 10A+10A range: 0.5mΩ~0.8Ω, 5A+5A range: 10mΩ~1.6Ω, 1A+1A range: 0.1Ω~8.0Ω, 0.1A+0.1A range: 2.0Ω~80Ω
Accuracy±(0.2% of reading + 2 digits)
Power SupplyAC220V±10%, 50/60Hz
Operating Temperature-10℃~50℃
Relative Humidity<90% (non-condensing)
Dimensions400×315×223mm
Weight9kg

D210-ST20A Resistance tester

  • Purpose and Application: The D210-ST20A plays a critical role in transformer handover testing by ensuring detection of issues such as poor connections, broken wires, and material defects in transformer windings and high-power inductive devices.

  • Key Features: It has three-phase resistor measurement with simultaneous three phase resistance measurement; rapid and accurate results, significant anti-interference; automatic discharge to enhance safety; and a built-in printer for documenting the results.

  • Technical Highlights: The present range of current and resistance values within which the D210 ST20A can operate are significant with accuracy at ±0.2% of reading + 2 digits, thus it can be conveniently relied on while conducting transformer tests.

D210-ST20A
D210-ST40A

D210-ST40A Resistance tester

  • Purpose: Tailored for testing the DC resistance of transformer windings and other high-power inductive apparatus, particularly during pre-delivery transformer tests.

  • Simultaneous Testing: Conducts YN three-phase DC resistance measurements simultaneously, yielding substantial time savings.

  • Accuracy and Speed: Provides rapid, accurate measurements with exceptional repeatability, anti-jamming, and data reliability.

  • Integrated Printer: Includes micro-printers of the panel type on the case which enable instant printing of result documents.

  • Versatility: Excellent for a broad spectrum of transformers and inductive devices, hence suitable for manufacturers and power companies.

D210-10A-D resistance tester

  • Purpose: Used to determine the DC resistance of transformer windings and high-power inductive devices which is critical for the transformer handover test prior to delivery.

  • Built-in Printer: Contains a micro printer type panel that conveniently documents measurement results.

  • Measurement Range: Works from 0.2mΩ to 10Ω which is fairly broad.

  • Current Range: Enables measurement of currents ranging from 0.2A to 10A.

  • Power Source: Requires AC220V at a frequency of 45Hz to 60Hz.

  • Accuracy: A high level of accuracy with measurement 0.2% ± 2 bits deviation at 25°C.

D210-10A-D
DRZ-211

DRZ-211 resistance tester

  • Application: The internal faults of transformers, such as winding deformations, inter-turn short circuits, or phase-to-phase contacts, can be diagnosed by appliable DRZ-211 Transformer Winding DC Resistance Tester using the most sophisticated Frequency Response Analysis (FRA) techniques.

  • Key Features: Test Precision and Diagnostic Confidence with FRA Frequency Response Analysis features. Arranged with microprocessor systems, the device ensures high speed performance, faultless diagnostics through DDS frequency sweep technology, dual channel 16 bit A/D sampling, and USB/WiFi communication peripherals. The device captures precise waveform variations and executes automatic test result analysis, word document generation inclusive.

  • Specifications: Delivers unrivaled transformer testing efficiency and reliability amidst compact design during other ±0.1dB amplitude accuracy and 10Hz - 10MHz frequency scope claim, unmatched test repeatability of 99.9%, and overall lightweight body of 10kg.

ParameterSpecification
Sweep Modes
Linear Frequency Sweep Range10Hz - 10MHz
Points40,000
Resolution0.25kHz, 0.5kHz, 1kHz
Segmented Frequency Sweep
Range 10.5kHz - 1MHz (2,000 points)
Sub-ranges0.5kHz - 10kHz, 10kHz - 100kHz, 100kHz - 500kHz, 500kHz - 1,000kHz
Technical Parameters
Amplitude Range-120dB to +20dB
Amplitude Accuracy±0.1dB
Frequency Accuracy0.01%
Test Repeatability99.90%
Physical Dimensions
Instrument Size (L×W×H)300 × 340 × 120 mm
Aluminum Case Size (L×W×H)310 × 400 × 330 mm
Total Weight10kg

DSC-211 (embedded type)

  • Purpose: The DSC-211 Transformer Winding DC Resistance Tester aims to cut down on the misuse of electrical power, like fee evasion or unauthorized capacity overloading, by measuring the parameters of the transformer precisely.

  • Automatic Features: It has automatic internal range switching for ease of primary voltage/current measurements, minimal wiring, simple phasor diagram verification, and automatic wiring check display for three phase transformers.

  • Testing Capabilities: Allows full current load tests for transformers up to 1000kVA and 1/3 rated current load tests for transformers up to 3150kVA with automatic zeroing to rated-current-loss parameters.

  • User Interface: 320×240 high-brightness LCD displays soft graphic menu with full Chinese guiding menu, operated with touch keys, backlight adjustable, and show phasor diagrams so straightforward they need no further explanation.

DSC-211 (embedded type)
CategoryParameterSpecification
Environmental ConditionsTemperature-5°C to 40°C
Relative Humidity<95% at 25°C
Altitude<2500m
InterferenceNo strong vibration or electromagnetic fields
Power Supply220VAC±10%, 45Hz~55Hz
Measurement RangeActive Part
Current Output0~10A
Voltage Measurement0~10V
Test CapacityDry-type: 30kVA~2500kVA
10kV Oil-immersed
20kV Dry-type: 50kVA~2500kVA
35kV Oil-immersed: 50kVA~31500kVA
35kV Dry-type: 50kVA~2000kVA
DSC-211

DSC-211 resistance tester

  • Multi-Functional and High-Precision Testing: The DSC-211 is a versatile instrument that integrates transformer capacity and characteristic parameter testing, measuring capacity, no-load and short-circuit losses, as well as impedance voltage with exceptional precision and reliability.

  • Enhanced Efficiency and Simplicity: It is lightweight, compact, and easy to operate; therefore, it streamlines the processes of wiring, testing, and recording, which replaces traditional multi-meter methods and enhances work efficiency.

  • Advanced Features for Accurate Results: The device is also equipped with features such as automatic range switching, wiring error detection, vector diagram display, and automatic corrections for measuring waveforms, temperature, voltage, and current ensuring precise measurements.

  • Wide Application Range: Designed for testing transformers up to 3150KVA; external voltage and current transformers are supported for greater measurement flexibility, broadening application uses.

CategorySpecifications
Environmental ConditionsTemperature: -5°C ~ 40°C
Relative Humidity: <95% (at 25°C)
Altitude: <2500m
External Interference: No extra-strong vibration or electromagnetic field
External Power Supply: 220VAC ±10%, 45Hz ~ 55Hz
Measuring RangeCurrent Output: 0 ~ 10A
Voltage Measurement: 0 ~ 10V
Test Capacity:
- 10kV oil-immersed & dry-type transformers: 30kVA ~ 2500kVA
- 35kV oil-immersed transformer: 50kVA ~ 31500kVA
- 20kV dry-type transformer: 50kVA ~ 2500kVA
- 35kV dry-type transformer: 50kVA ~ 2000kVA
FeaturesVoltage: 0 ~ 600V (automatic switching range inside the instrument)
Current: 0 ~ 100A (automatic switching range inside the instrument)
Frequency: 45Hz ~ 65Hz
Accuracy of the TestVoltage: 2 ~ 100V, ±0.2%FS; 100 ~ 450V, ±0.2%
Current: 0.5 ~ 10A, ±0.2%FS; 10 ~ 100A, ±0.2%
Power: ±0.5% (Cos Φ > 0.1), ±1.0% (0.02 < Cos Φ < 0.1)
Dielectric StrengthVoltage & Current Input: 100mΩ insulation resistance of casing
Power Frequency: 2kV (effective value) between housing and input, lasting 1 minute
Other IndicatorsExternal Dimension: 400×300×170mm
Weight: 6kg (excluding test line)

DYZ-209 winding resistance tester

  • Purpose: With the DYZ-209 Tester, one can assess and analyze the electrical operational characteristics of on-load tap changers in power and special transformers.

  • Key Measurements: The device does precise measurements of OLTC features such as transition period waveform, resistance values, and three-phase synchronization. Such measurements are done with superb precision.

  • Features: Solves problems pertaining to data display, analysis, storage, and printing for OLTC tests. Also provides a dedicated solution for other OLTC testing methods.

  • Benefits: Enhancing transformer dependability while improving power system performance allows for more reliable fault detection during maintenance.

DYZ-209
ParametersindicatorsParametersindicators
Voltage input>20VPower supply AC220V±10%,50Hz
Voltage output≥1APower 180W
 Resistance measurement range0.3~40ΩResistance measurement accuracy0.1Ω~1Ω±0.1Ω,1Ω~40Ω±5%±0.1Ω
Time measurement range1ms~256msTime measurement accuracy1ms~100ms±0.1ms, 100ms~250ms±1%
Three-phase synchronization0.1msSampling frequency10~20KHz
Operating temperature0~40℃Operating humidity≤80%RH
dimension420mm, 350mm, 220mmweight12kg(apparatus are included)
DZK-207

DZK-207 resistance tester

  • Application: The tester assesses the transformer winding deformation from short-circuit currents or mechanical shocks for operation, transport, or installation.

  • Key Measurements: Presents and measures short-circuit impedance and reactance of transformers, three-phase impedance voltage, and voltage, current, power, and frequency. Measure and display voltage, current, power, frequency.

  • Power Supply Options: Single-phase 220V AC or low-power UPS (500VA). Operate with Internal/external power supply options.

  • Ease of Use: Wiring ease and simple operation, automatic three phase measurement with direct display of results. Managing voltage and current auto adjustment free of hinderance.

ParameterSpecification
Voltage20V ~ 400V
Current0.5A ~ 10A
AccuracyVoltage/Current: Class 0.2
Impedance: Class 0.5
Dimensions350mm × 270mm × 170mm

Transformer DC Resistance Test: Understanding Winding Resistance Measurements

The key aspects where the Transformer DC Resistance Test proves helpful are evaluating performance, identifying defects such as malfunctioning connections or aging, and assisting in proactive maintenance. This blog discusses the test’s functioning, methods, and advantages to ensure the dependable operation of transformers.

995f9ce8 line4 1
Featured Blog Topics

Insights, Tips & Trends

Scroll to Top
Get in touch with DEMIKS company
Contact Form 在用