
Partial discharge testing gets criticized as being too complicated- circuits have way too many components, there
Are you in search of the most appropriate Accumulator Cell Intelligent Activator for your enterprise? Here at DEMIKS, we have everything you need. All of your battery-related requirements will be taken care of through our advanced technology that guarantees unsurpassed accuracy and effectiveness. Rely on the professionals at DEMIKS, and we will make sure that you get the best products available in the market.
Battery Rejuvenation: Straightforward battery activation and repairs through low-voltage, surge-free, high-current technology.
Safe Discharge Capabilities: The PTC resistors are surge-proof and low power. Overcurrent cut-off for safety and long lifespan.
Superior Grade CPU: Efficient performance through the use of dual ARM CPUs provides system stability.
Integrative Alarm Configuration: Discharge and charge alerts, fault detection surpassed by no other.
Abundant Resources: Capable of Data set surpassing Auxiliary holds 16GB memory over 1000 data.
Preprogrammed Facets: Operation templates provide easy activation, configuration, and operation.
| Category | Specification |
|---|---|
| Test Functions | Constant current discharge, capacity analysis, constant voltage/current charging, cyclic activation |
| Model | 2V/6V/12V |
| Charging Voltage Range | DC 1.5V~15V |
| Charging/Discharge Current Range | 2V: 1100A, 6V: 160A, 12V: 1~30A |
| Display Function | 7” LCD touch screen, resolution: 1024x800 |
| Voltage Measurement Range | ±0.5%FS+0.01V |
| Current Measurement Range | ±1%FS+0.1A, max measuring range: 100A |
| Single Cell Voltage Display Accuracy | 0.01V |
| Current Display Accuracy | 0.01A |
| Data Storage Capacity | Built-in: 16Gbit FLASH; External: 16G storage |
| Data Communication | USB*1 |
| Working Modes | Constant current, constant power, constant voltage, cyclic activation, parallel/slave control |
| Protection Performance | LCD alert + buzzer alarm |
| Host Protection | Over temperature, over current, current out of control trigger shutdown |
| Reverse Connection Protection | Acoustic and optical alarm for polarity connection |
| Over-Temperature Protection | Stops discharging if temperature exceeds 75℃ |
| Heat-Dissipating Method | Forced air cooling |
| Temperature | Working: -550℃, Storage: -4070℃ |
| Humidity | Relative humidity: 0~90% (40±2℃) |
| Altitude | Rated altitude ≤4000 m |
| Working Power | Voltage: Single-phase three-wire system: 220V AC (–20%+30%), Frequency: 4565Hz |
| Voltage Withstand Test | Input to housing: 2200V DC 1min; Output to housing: 700V DC 1min |
| Safety | Meets EN610950, GB/T 31484-2015 battery maintenance technical specifications |
| Overall Dimension | 390*215*290mm |
| Weight | 13kg |
| Remark | Includes moisture-proof aluminum alloy rod box; custom voltage/current levels available upon request |
This guide is designed to demystify the inner workings of the accumulator generator, breaking down its principles, functionality, and critical applications across various industries.

Partial discharge testing gets criticized as being too complicated- circuits have way too many components, there

Common mistakes in onsite PD testing are not arcane edge cases — they recur on energized
![Partial Discharge Test Equipment: Types, Selection & IEC 60270 Guide [2026]](https://demikspower.com/wp-content/uploads/2026/05/0-10.webp)
Choosing the right partial discharge test equipment for transformers, HV cables, GIS, or rotating machines is
WhatsApp us